三相电路有功功率、无功功率、视在功率及功率因数计算公式
三相电路是工业供电的基本形式。本文从一般三相电路出发,系统推导各种功率的计算公式。
一、一般三相电路的功率
无论三相电路是否对称,其瞬时功率、平均功率和无功功率均为各相对应功率之和。文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
1. 有功功率(平均功率)
三相负载吸收的总有功功率等于各相有功功率之和:文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
$P = P_A + P_B + P_C = U_{PA} I_{PA} \cos\varphi_A + U_{PB} I_{PB} \cos\varphi_B + U_{PC} I_{PC} \cos\varphi_C$文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
对称三相电路
当三相电路对称时,各相功率相等:文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
$P_A = P_B = P_C$文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
因此总的对称三相有功功率为:文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
$P = 3 \cdot U_P \cdot I_P \cdot \cos\varphi$文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
利用线电压与相电压的关系(对称三相电路中,无论星形还是三角形连接,$3U_P I_P = \sqrt{3}U_L I_L$ 恒成立):文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
$P = \sqrt{3} \cdot U_L \cdot I_L \cdot \cos\varphi$文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
式中 $\varphi$ 为相电压与相电流的相位差(负载阻抗角),$\cos\varphi$ 为功率因数。文章源自公式库网-https://www.gongshiku.com/html/201808/sanxiangdianludeyougonggongshuaiwugonggongshuaishizaigongshuaisanxiangfuzaidegongshuaiyinshujisuangongshi.html
二、无功功率
三相负载的无功功率等于各相无功功率之和:
$Q = Q_A + Q_B + Q_C$
对称三相电路中:
$Q = \sqrt{3} \cdot U_L \cdot I_L \cdot \sin\varphi$
三、视在功率
三相视在功率定义为:
$S = \sqrt{P^2 + Q^2}$
在对称情况下:
$S = \sqrt{3} \cdot U_L \cdot I_L$
四、三相负载的功率因数
三相负载的功率因数定义为有功功率与视在功率的比值:
$\cos\varphi = \dfrac{P}{S}$
对对称三相电路,$\cos\varphi$ 就是每相负载的功率因数。工业用电中要求 $\cos\varphi \geq 0.9$,功率因数过低将导致线路损耗增大、设备利用率下降,需要安装无功补偿装置进行改善。
五、公式速查表
| 功率类型 | 一般公式 | 对称三相公式 |
|---|---|---|
| 有功功率 $P$ | $P = \sum P_k$ | $P = \sqrt{3}U_L I_L \cos\varphi$ |
| 无功功率 $Q$ | $Q = \sum Q_k$ | $Q = \sqrt{3}U_L I_L \sin\varphi$ |
| 视在功率 $S$ | $S = \sqrt{P^2 + Q^2}$ | $S = \sqrt{3}U_L I_L$ |
| 功率因数 | $\cos\varphi = P/S$ | $\cos\varphi = P/S$ |